As a panel-mounted instrument, PMC200S achieves accurate measurement of highly nonlinear loads based on the measurement of rms. Advanced grid frequency simultaneous sampling technology enables it to accurately measure a wide range of power parameters, including voltage/current, frequency, power, power factor, energy and current/voltage harmonics.
Compared with traditional energy meters, PMC200S has both data acquisition and control functions, compact size, easy-to-deploy and cost-saving features, and can be widely used in energy management systems, substation automation, distribution network automation, community power distribution, industrial automation, power plant power systems, intelligent buildings, intelligent distribution panels, high and low voltage switchgear and other scenarios.
By using the PMC200S, you can gain insights into power load conditions, identify peak energy consumption periods, and take targeted energy-saving measures. Our product offers a 485 communication interface, allowing you to interact with other devices and smart systems, enabling more intelligent energy management.
We are committed to providing you with comprehensive and reliable energy monitoring and management solutions, helping you achieve energy-saving and emission reduction goals while improving cost-effectiveness. Choose our multifunctional meter, and you will enjoy advanced technology, convenient operation, and a durable quality guarantee.
Electrical characteristics | ||
System | Three-phase three-wire AC system, three-phase four-wire AC system; | |
Sample rate | 128 samples per cycle | |
Data refresh rate | 1s | |
Measurement accuracy | Current | ±0.2%FS |
Voltage | ±0.2%FS | |
Power | 0.5S | |
Frequency | ±0.001Hz | |
Active energy | 0.5S | |
Reactive energy | 1.0S | |
DC input (AI) | 0.5% FS | |
DC output (AO) | 0.5% FS | |
Voltage input | Measure voltage | 3*220/380V(Direct input) |
3*57.7/100V (PT secondary) | ||
Overload | 1.2x/continuous | |
Input impedance | 300KΩ | |
Current input | Measure current | 5A (CT secondary) or 1A (CT secondary) |
Overload | 1.2x/continuous | |
Input impedance | <0.1Ω | |
Digital input | Operating voltage | 12~24VDC |
Input impedance | 12KΩ | |
Isolation voltage | 2KV | |
Digital output | Node type | Mechanical contacts |
Node capacity | 220 VAC/5A,30 VDC/5A | |
4~20mA DC input measurement | Measure current | 4~20mA |
Allowed overload capacity | 1.2x/continuous | |
Input impedance | 10Ω | |
Isolation voltage | 2KV | |
0~5V DC input measurement | Measure voltage | 0~5V |
Allowed overload capacity | 1.2x/continuous | |
Input impedance | 12.5KΩ | |
Isolation voltage | 2KV | |
4~20mA DC output | Open-circuit voltage | 15VDC |
Load capacity | ≤600Ω | |
Isolation voltage | 2KV | |
Working power supply | AC | 100~240VAC/45~65Hz |
DC | 100~375 VDC | |
power consumption | < 3W | |
Mechanical characteristic | ||
Weight | 0.5kg | |
IP protection rating | Instrument panel IP52, instrument body IP30 | |
Size | host | 96 *96 * 72 mm |
Host + module | 96 * 96 * 120 mm | |
Operating temperature | display | -20~70°C |
Instrument | -25~70°C | |
Storage temperature | instrument + display | -40~85°C |
Humidity | 5% ~ 90%RH, non-condensing | |
Electromagnetic compatibility | ||
Electrostatic discharge | IEC 61000-4-2, Level 4 | |
Fast transient | IEC 61000-4-4, Level 4 | |
Surges | IEC 61000-4-5, Level 3 | |
Magnetic fields | IEC 61000-4-8, Level 3 | |
Electrical insulation | ||
Insulation resistance | GB/T13729,>50MΩ | |
AC voltage | GB/T13729, AC 2KV 50Hz /1min | |
Impulse voltage | GB/T13729,5KV,1.2/50us |
Embed the meter into the 90mm*90mm cutout slot and screw on the fixing buckle.
At Kingnen, the packaging process for energy meters is carefully executed to ensure secure and damage-free delivery. Each meter undergoes thorough testing and quality control before being individually wrapped and protected with cushioning materials. Sturdy cartons and added layers of protection are used for enhanced safety. Accurate labeling and documentation are applied to each package. Our meticulous approach guarantees that our energy meters arrive in optimal condition, ready for installation. We prioritize product integrity and customer satisfaction throughout the packaging process.
1. Are expansion modules necessary?
Input/output expansion modules are not necessary, but they allow for features such as switch status monitoring, relay outputs, DC voltage and current input monitoring, and transmitters. We can also provide customization based on your specific requirements.
2.How many PMC200S can be configured under the same acquisition node?
Using a Category 5e shielded twisted pair cable, you can configure up to 32 devices under the same node. If there are no repeaters, the total bus length should not exceed 1200 meters.