Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 2 Years
Still deciding? Get samples of US$ 75/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 10 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
to see all verified strength labels (30)
  • Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter
  • Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter
  • Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter
  • Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter
  • Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter
  • Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Dimensions & Mounting
  • Application
  • Company Profile
  • Certifications
  • Trade Shows
Overview

Basic Info.

Model NO.
PMC96S
Display
Digital
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Three-wire
Theory
Electronic Meter
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Communication
RS-485/Modbus-RTU Protocol
Compound Rate of Electrical Energy
8 Multi-Rated Periods, 4 Rates Can Be Set
Real-Time Clock
Year, Month, Day, Minute, Second
Weight
0.5kg
Transport Package
Carton
Specification
96 X 96X 102mm
Trademark
KINGNEN
Origin
China
Production Capacity
2000/Month

Product Description


PMC96S meter is a multi-functional power monitoring meter, it combines function of collecting data and control, and it can replace many kind of meters, relays, transformers and others components. PMC96S can be installed in different positions of electricity distribution system.
Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter
 
Product Description
 

Host features

Instantaneous true RMS value

Current each single phase and conjunction, average

Phase voltage/line voltage each single phase and conjunction, average

Active, reactive, apparent power each phase and the sum of three phases

Power factor each phase and the sum of three phases

Frequency 45~65Hz

Maximum/minimum value

Max/min rms current

Max/min rms phase voltage

Max/min total active, reactive, apparent power

Max/min total power factor

Max/min frequency

Max/min THD I and THD U

Demand and peak demand value

Current per phase current value/peak/month end peak

Total active, total reactive, total apparent power current value/peak/month end peak

Energy

Input/output/total active energy 1 pulse output

Input/output/total reactive energy 1 pulse output

Apparent electrical energy

Monthly electrical energy

Compound rate of electrical energy

8 multi-rated periods, 4 rates can be set

Power quality

Total Harmonic Distortion Rate (THD) current and voltage

1st-31st harmonic analysis current and voltage

Voltage crest factor CF and current K coefficient

Event logging

100 SOE event records

Alarm system

8 configurable limit alarm channels

4 configurable logical alarm channels

Communication

RS-485 /MODBUS-RTU Protocol

Display

STN LCD display

Real-time clock

Year, month, day, minute, second

Other

Program online upgrade supported

 

Optional features

Digital Input (DI) module (optional)

2 switching inputs

Digital Output (DO) module (optional)

2 relay outputs, which can be set by local overrun alarm or controlled remotely

Analog Input (AI)/Output (AO) module (optional)

2 channels. 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output optional.

 
Product Parameters
 

Electrical characteristics

System

Three-phase three-wire AC system, three-phase four-wire AC system;

Sample rate

128 samples per cycle

Data refresh rate

1s

Measurement accuracy

Current

±0.2%FS

Voltage

±0.2%FS

Power

0.5S

Frequency

±0.001Hz

Active energy

0.5S

Reactive energy

1.0S

DC input (AI)

0.5% FS

DC output (AO)

0.5% FS

Voltage input

Measure voltage

3*220/380V (Direct input)

3*57.7/100V (PT secondary)

Overload

1.2x/continuous

Input impedance

300KΩ per phase

Current input

Measure current

5A (CT secondary) or 1A (CT secondary)

Overload

1.2x/continuous

Input impedance

<0.1Ω

Digital input

Operating voltage

15 VDC

Input impedance

12 KΩ

Isolation voltage

2 KV

Digital output

Node type

Mechanical contacts

Node capacity

220 VAC/5A,30 VDC/5A

4~20mA DC input measurement

Measure current

4~20mA

Allowed overload capacity

1.2x/continuous

Input impedance

10 Ω

Isolation voltage

2 KV

0~5 V DC input measurement

Measure voltage

0~5 V

Allowed overload capacity

1.2x/continuous

Input impedance

12.5 KΩ

Isolation voltage

2 KV

4~20mA DC output

Open-circuit voltage

15 VDC

Load capacity

≤600 Ω

Isolation voltage

2 KV

Working power supply

AC

100~240 VAC/45~65Hz

DC

100~375 VDC

power consumption

< 3 W

Mechanical characteristic

Weight

0.5 kg

IP protection rating

Instrument panel IP52, instrument body IP30

Size

host

96 *96 * 72 mm

Host + module

96 * 96 * 120 mm

Operating temperature

display

-20~70°C

Instrument

-25~70°C

Storage temperature

instrument + display

-40~85°C

Humidity

5% ~ 90%RH, non-condensing

Electromagnetic compatibility

Electrostatic discharge

IEC 61000-4-2, Level 4

Fast transient

IEC 61000-4-4, Level 4

Surges

IEC 61000-4-5, Level 3

Magnetic fields

IEC 61000-4-8, Level 3

Electrical insulation

Insulation resistance

GB/T13729,>50 MΩ

AC voltage

GB/T13729, AC 3KV 50Hz /1min

Impulse voltage

GB/T13729,5KV,1.2/50us

 
Dimensions & Mounting

The size of the instrument and cutout is shown below (Unit: mm).
Three Phase RS485 Modbus Output Measuring Digital Multifunction Power MeterThree Phase RS485 Modbus Output Measuring Digital Multifunction Power MeterThen Embed the meter into the 90mm*90mm cutout slot and screw on the fixing buckle, as shown in the picture followed.
Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter

Application

The instrument, as shown in the figure below, is in charge of measuring and collecting power data for each loop and is located in the collection layer. Simultaneously, the instrument equipped with a DI/DO and an AO module may achieve switch status monitoring, relay output, and a transmitter, all of which can be adjusted to your specific requirements.
Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter

Company Profile

Kingnen has been focusing on power metering and energy monitoring and management solutions for 20 years. Our products are widely used in the fields of electric power, large-scale buildings and renewable energy, the products have passed UL, CE and other certifications, we have cooperated with the world's top 500 company continously. Last but not least, we provide OEM/ODM services.
Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter

Certifications

Three Phase RS485 Modbus Output Measuring Digital Multifunction Power MeterThree Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter

Trade Shows

Three Phase RS485 Modbus Output Measuring Digital Multifunction Power Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier